{"id":773,"date":"2012-08-03T13:27:00","date_gmt":"2012-08-03T13:27:00","guid":{"rendered":"http:\/\/www.cleartek.co.uk\/wordpress\/?page_id=773"},"modified":"2013-08-01T14:46:48","modified_gmt":"2013-08-01T14:46:48","slug":"conical-settlement-tanks","status":"publish","type":"page","link":"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/","title":{"rendered":"Conical Settlement Tanks"},"content":{"rendered":"<p><img decoding=\"async\" alt=\"\" src=\"http:\/\/\" \/><a href=\"http:\/\/www.cleartek.co.uk\/wordpress\/wp-content\/uploads\/2012\/08\/con1.gif\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-full wp-image-905\" title=\"conical tank\" alt=\"\" src=\"http:\/\/www.cleartek.co.uk\/wordpress\/wp-content\/uploads\/2012\/08\/con1.gif\" width=\"157\" height=\"187\" \/><\/a>Conical tanks for settlement of raw sewage,secondary treated effluent and industrial waste waters.<\/p>\n<p><strong>Features<\/strong><\/p>\n<ul>\n<li>GRP construction with corrosion resistant reinforcement<\/li>\n<li>Resistant to almost all chemicals &#8211; tanks can be made to withstand very strong alkalis or acids<\/li>\n<li>60\u00b0 inverted cone tank.<\/li>\n<li>An increased retention period can be produced by extending straight heights<\/li>\n<li>Can be installed either below or above ground (up uo 4.0m diameter)<\/li>\n<li>Sized in accordance with BS 6297 and designed to principles established in BS4494<\/li>\n<li>Supplied complete with internal launders, diffusion drum, scum board, piping etc.<\/li>\n<li>Connection sizes and positions tailored to customer needs Scum draw-off systems available<\/li>\n<\/ul>\n<p><strong>Contact Cleartek:<\/strong> To find out more about our range of range of environmentally friendly Sewage Treatment and Water Polution Control Plants or to request a free quotation Contact Cleartek Services<\/p>\n<p><strong>Sewage Treatment Plants and Installation<\/strong><br \/>\n<strong> Cleartek Ltd<\/strong> : Glenhaven : College Road : Methven : Perth : Scotland : PH1 3PB : Tel and Fax: 01738 842875<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conical tanks for settlement of raw sewage,secondary treated effluent and industrial waste waters. Features GRP construction with corrosion resistant reinforcement Resistant to almost all chemicals &#8211; tanks can be made to withstand very strong alkalis or acids 60\u00b0 inverted cone tank. An increased retention period can be produced by extending straight heights Can be installed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1057,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conical Settlement Tanks - Cleartek Services\" \/>\n<meta property=\"og:description\" content=\"Conical tanks for settlement of raw sewage,secondary treated effluent and industrial waste waters. Features GRP construction with corrosion resistant reinforcement Resistant to almost all chemicals &#8211; tanks can be made to withstand very strong alkalis or acids 60\u00b0 inverted cone tank. An increased retention period can be produced by extending straight heights Can be installed [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/\" \/>\n<meta property=\"og:site_name\" content=\"Cleartek Services\" \/>\n<meta property=\"article:modified_time\" content=\"2013-08-01T14:46:48+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data1\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/#website\",\"url\":\"http:\/\/www.cleartek.co.uk\/wordpress\/\",\"name\":\"Cleartek Services\",\"description\":\"Pure Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/www.cleartek.co.uk\/wordpress\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/\",\"contentUrl\":\"http:\/\/\"},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#webpage\",\"url\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/\",\"name\":\"Conical Settlement Tanks - Cleartek Services\",\"isPartOf\":{\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#primaryimage\"},\"datePublished\":\"2012-08-03T13:27:00+00:00\",\"dateModified\":\"2013-08-01T14:46:48+00:00\",\"breadcrumb\":{\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/\",\"url\":\"http:\/\/www.cleartek.co.uk\/wordpress\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.cleartek.co.uk\/wordpress\/treatment\/\",\"url\":\"https:\/\/www.cleartek.co.uk\/wordpress\/treatment\/\",\"name\":\"Treatment Systems\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/\",\"url\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/\",\"name\":\"Tertiary Treatment\"}},{\"@type\":\"ListItem\",\"position\":4,\"item\":{\"@id\":\"http:\/\/www.cleartek.co.uk\/wordpress\/treatment\/tertiary-treatment\/conical-settlement-tanks\/#webpage\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/pages\/773"}],"collection":[{"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/comments?post=773"}],"version-history":[{"count":17,"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/pages\/773\/revisions"}],"predecessor-version":[{"id":1256,"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/pages\/773\/revisions\/1256"}],"up":[{"embeddable":true,"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/pages\/1057"}],"wp:attachment":[{"href":"http:\/\/www.cleartek.co.uk\/wordpress\/wp-json\/wp\/v2\/media?parent=773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}